Ozone aging tank
|
Ozone aging test chamber |
|||||||
|
Specifications and models |
TCY-100 |
TCY-150 |
TCY-250 |
TCY-500 |
TCY-010 |
||
|
Studio Size (cm) |
50x40x50 |
50x50x60 |
60x60x70 |
80x70x90 |
100 x100x100 |
||
|
temperature range |
A: -10℃~80℃ B: RT+10℃~80℃ |
||||||
|
ozone concentration |
A:10~500pphm B :5~200ppm C:5~500ppm D:5~1000ppm |
||||||
|
ozone control accuracy |
5%/10% |
||||||
|
sample |
10~100% adjustable (dynamic stretch) |
||||||
|
shelf rotation speed |
1-3R/min (dynamic tension) |
||||||
|
Waviness/Uniformity |
± 0.5 ℃ /± 2 ℃ |
||||||
|
gas flow velocity |
≦1m/s |
||||||
|
humidity range |
50%~95%RH |
||||||
|
humidity deviation |
-2% to-3% |
||||||
|
working noise |
≤72 dB(A) |
||||||
|
Sample rack load bearing |
≤ 20kg |
||||||
|
operating power |
~ 3.25KW |
~ 3.55KW |
~ 3.95KW |
~ 5.5KW |
~ 6.25KW |
||
|
material |
liner:# SUS 304 stainless steel |
shell: cold plate spray/#SUS304 stainless steel wire drawing |
|||||
|
Wind circulation mode |
Centrifugal impeller forced drive |
||||||
|
refrigeration mode |
Single stage refrigeration/double cascade |
||||||
|
Compressor |
French "Taikang"/American "Copeland" |
||||||
|
Refrigerant |
R4O4A DuPont Environmental Refrigerant/R23 |
||||||
|
cooling method |
Air cooling or water cooling |
||||||
|
heater |
316L seamless stainless steel fin heater/nickel-chromium alloy heating wire heater |
||||||
|
humidifier |
External stainless steel boiler humidifier |
||||||
|
Water filling method |
Automatic cycle replenishment mode |
||||||
|
control instrument |
TEMI880 or OYO-8256P or HLS950or E300 |
||||||
|
related standards |
JISK6259 ASTM1149 GB/T13642 GB/T7762 GB/T2951.21 GB/T 11206 |
||||||
|
standard fittings |
1 observation window (multi-layer hollow heat conduction anti-fog type) 1 50mm test hole 1 U-shaped energy-saving lamp 1 Sample rack 1 wet and dry ball gauze 3 Resettable Fuse 1 power supply cable 3 m. |
||||||
|
safety device |
compressor overload protection humidifier protection against dry burning Mechanical over-temperature insulation Water tank water shortage protection |
||||||
-
Environmental Test Equipment
-
Constant Temperature and Humidity
-
High and Low Temperature
-
Constant Higt Constant Temperature Test
-
Rapid Temperature Change Chamber
-
Thermal Shock Test Chamber
-
Sand Test Chamber
-
Rain-Spray/Drip Device Test
-
Xenon Lamp Climatic Test
-
Aging test chamber
-
Walk-in/Mobile Test Chamber
-
Black Garlic Fermentation Box
-
Drug Stability Test Chamber
-
Salt Spray Corrosion Test Chamber
-
Triple Combined Test Chamber
-
Low-Temperature Liquid Nitrogen Test
-
Vacuum Dry Oven
-
-
Fluid Temperature Control Equipment
-
Customized Non-standard Test Chambers